If your device is not designed with a single IP method, please follow the procedures below to verify the IP change process. All IP addresses below must be distinct. Ensure you keep detailed modification records during the process.
| Change Sequence | Application Type | Instructions |
|---|---|---|
| Visible Light Camera IP | For network camera input, confirm camera IP modification first | Change via web login |
| Thermal Infrared Camera IP | For network camera input, confirm camera IP modification first | Change via web login |
| Digital Interface Camera | No action required | |
| Serial Server IP | Modify IP via web login. Default IP: 192.168.1.66 If modified previously, check Serial Server IP in TVMS client |
Change via web login. Default credentials: admin/12345678 Do not modify configurations beyond IP address |
| Laser Fill Light/ Laser Rangefinder Serial Server IP |
Modify IP via web login. Default IP: 192.168.1.88 If modified previously, check Laser Rangefinder IP in TVMS client |
Change via web login. Default credentials: admin/12345678 Do not modify configurations beyond IP address |
| Tofu Module IP | 1. Modify local IP via TVMS client 2. Re-add login for new IP 3. Modify Serial Server IP configuration 4. For network camera input devices: modify stream URL 5. Update Laser Rangefinder IP |
Execute steps sequentially. Skip irrelevant device types |
Recommend using router NAT mapping or single-IP modules for IP mapping. In such cases, only modify the mapped address.